Retrofit architectures

Seven ways to make a mechanical lock smart. They differ in how much they change the door, whether they keep the key, and which adapters have to be designed.

ArchitectureDoor untouchedKeeps keyDifficultyFits
Motor on the thumb-turn ●○○○ Euro profile cylinder in a mortise case (DIN), UK oval cylinder (uPVC and composite doors), Multipoint locking system (uPVC / composite)
Electronics integrated in the cylinder ●●●○ Euro profile cylinder in a mortise case (DIN), UK oval cylinder (uPVC and composite doors)
Motor replacing the interior handle ●●○○ Euro profile cylinder in a mortise case (DIN), Singapore HDB main-door mortise set and metal gate lock, Australian deadlatch and deadlock, Korean push-pull digital lock base (mortise)
Surface motor on a deadbolt turn-piece ●○○○ Single-cylinder deadbolt (ANSI/BHMA A156.36), Rim nightlatch (surface-mounted), Japanese mortise case and cylinder (MIWA / GOAL style)
Full lock replacement on the same footprint ●●●● Singapore HDB main-door mortise set and metal gate lock, Korean push-pull digital lock base (mortise), Japanese mortise case and cylinder (MIWA / GOAL style), Mortise lockset (ANSI/BHMA A156.13), Australian deadlatch and deadlock
Motor on a rim (surface-mounted) lock ●●○○ Rim nightlatch (surface-mounted), Australian deadlatch and deadlock, Padlock, hasp and staple
Gate actuator (lever, chain or magnetic) ●●●○ Singapore HDB main-door mortise set and metal gate lock

Engineer feedback